HAFBLF0200C4AX3
Honeywell Sensing & Control Also known as: Foxboro ICT, Honeywell Control Products, Honeywell Micro Switch, Honeywell Optoelectronics, Micro Switch/Honeywell, SenSym ICT
Category: Sensors
Description: Honeywell ZephyrT Digital Airflow Sensors: HAF Series-High Accuracy, bidirectional flow, long port, fastener mount, 0 SCCM t
Avg. Price $146.6 | Auth QOH 0 | Ind QOH 0
Part Status: Obsolete
Lead Time: No lead time information available
Detailed information:
- Total Error Band (TEB) as low as ±0.25 %FSS: Allows for precise airflow measurement, often ideal for demanding applications with high accuracy requirements
- Fast response time: Allows a customer's application to respond quickly to airflow change, important in critical medical (e.g., anesthesia) and industrial (e.g., fume hood) applications
- Wide range of airflows: Zephyr measures mass flow at standard flow ranges of ±50, ±100, ±200, ±400 or ±750 SCCM, or custom flow ranges, increasing the options for integrating the sensor into the application
- Customizable flow ranges and configurable package styles: Meet specific end-user needs
- Full calibration and temperature compensation: Typically allow customer to remove additional components associated with signal conditioning from the PCB, reducing PCB size as well as costs often associated with those components (e.g., acquisition, inventory, assembly)
- Linear output: Provides a more intuitive sensor signal than the raw output of basic airflow sensors, which can help reduce production costs, design, and implementation time
- Low pressure drop: Typically improves patient comfort in medical applications, and reduces noise and system wear on other components such as motors and pumps
- High 12-bit resolution: Iincreases ability to sense small airflow changes, allowing customers to more precisely control their application
- Low 3.3 Vdc operating voltage option and low power consumption: Allow for use in battery-driven and other portable applications
- ASIC-based I2C digital output compatibility: Eases integration to microprocessors or microcontrollers, reducing PCB complexity and component count
- Insensitivity to altitude: Eliminates customer-implemented altitude adjustments in the system, easing integration and reducing production costs by not having to purchase additional sensors for altitude adjustments
- Small size: Occupies less space on PCB, allowing easier fit and potentially reducing production costs; PCB size may also be reduced for easier fit into space-constrained applications
- RoHS-compliant materiasl: Meet Directive 2002/95/EC
Medical:
- Anesthesia delivery machines
- Ventricular assist devices (heart pumps)
- Nebulizers
- Oxygen concentrators
- Patient monitoring systems (respiratory monitoring)
- Sleep apnea machines
- Spirometers
- Ventilators
- Laparoscopy
Industrial:
- Air-to-fuel ratio
- Fuel cells
- Gas leak detection
- VAV system on HVAC systems
- Gas meters
- HVAC filters